Experts debate power distribution options

Experts debate power distribution options

By:  Robert L Mitchell  On: 29 Oct 2007 For: Computerworld Creator

Alternating current became the standard because it was more practical from a cost and efficiency standpoint, but forthcoming research could give Thomas Edison's direct current a decided advantage in the data centre

It was last century that inventor Nikola Tesla came up with a rival to Thomas Edison's direct current design, the alternating current network, which trumped to become the standard for electric power distribution networks

AC won because it was more practical. It was the more efficient and economical way to transmit power over long distances. Now the debate has risen anew, and passions are again running high. But this time, the battleground is over which is most energy efficient -- and practical -- as the distribution network for increasingly power-constrained data centres.

Edison may finally have his revenge. Or will he?

"You'll find people who are religiously convinced in both directions," says John Pflueger, technology strategist at Dell and a board director at The Green Grid consortium. Many of those debates are raging within companies that are building new data centre equipment, and The Green Grid is at the center. It launched a power distribution options study, due by year's end, which is investigating seven alternatives. Three of those specify DC voltages.

IT equipment power supplies convert incoming AC power to the various DC voltages the subcomponents require. While some equipment also accepts DC input power, most data centres distribute 208-volt AC out to the racks. At least 10 per cent of the AC power coming into data centres is lost to AC/DC and DC/AC conversion inefficiencies before it reaches the IT equipment. "Every conversion step is maybe 90 per cent efficient on a good day," says HP senior technologist and Green Grid board director Roger Tipley. That wasted energy creates heat that must be removed, increasing air conditioning loads.

DC returned to the forefront with the 2006 release of a paper by Lawrence Berkeley National Laboratory researcher William Tschudi. It showed a 20 per cent overall efficiency gain in the data centre by moving to a 380-volt DC power distribution scheme. "Distributing DC would be relatively easy," Tschudi says.

That has some IT executives excited. "We're studying it for a new data centre we're looking at building in the next two and a half years," says Bob Culver, senior vice-president and manager of technology information group facilities at Wells Fargo. Joseph Hedgecock, senior vice president and head of platform and data centres at Lehman Brothers, says he is also taking a hard look at DC.

"There's a lot of buzz, and a lot of interest in using DC power in the data center," says Peter Gross, CEO at EYP Mission Critical Facilities, which designs data centres.

But DC is far from a slam-dunk. Of the three proposed DC voltages, only the smallest -- the --48-volt telco facility standard -- is in use today. But such low voltage requires high current, and thus large cables, to deliver the kind of power that large data centers need. The distribution rails required could resemble an overhead train trestle. A proposed 380-volt standard would use lower current and thus smaller conductors. It also exactly matches the uninterruptible power supply's operating voltage, making it very efficient. A proposed 550-volt DC standard would use even smaller cables. But using either 380- or 550-volt DC would require the development of an entirely new infrastructure.


Sign up for our Newsletters












Print |  Views: 992   |   Rating:offoffoffoffoff  (0 votes)
Rate this article on a scale of
1 to 5 stars,5 being the best.




Robert L Mitchell Robert L Mitchell is a contributor to the International Data Group (IDG) News Service, which publishes global technology stories from bureaus around the world to more than 300 publications in more than 60 countries.

Related Content

Chloride launches new UPS module
Chloride launches new UPS moduleThe U.K.-based company said the scalable, high-capacity UPS system fits in well into data centres, hospitals and other large commercial buildings.
Kelowna firm spends $75M on green data centre
Kelowna firm spends $75M on green data centreA partnership between IBM Canada and RackForce will see an energy-efficient facility built for the customers of gigaCenter Services Corp. Why location matters as much as the technology
The Green Data Centre: Cooling
The Green Data Centre: CoolingCooling can eat up a third of your data centre power bill. Take advantage of an overlooked natural resource: our cold climate
It takes courage to admit your product is insecure
kudos to mozzila's chief security officer, window snyder (yes, that's his real name), who
YouTube Fridays: A sock puppet learns about SAS
i don't know what the prize was, but business intelligence vendor sas institute recently launched an employee video contest where staffers had to try and explain the power of its product line. this clip only came in second place, but i lo
New indoor modem from Vecima
vecima networks has released what it calls the waverider next generation indoor modem for its lms8000 series 900 mhz linup. the new eum8005 indoor radio  offers what the victoria, b.c., company says is the highest throughput ofdm indoor subscriber unit in the indust

Comments (0)

No Comments!
Name: (required) eMail: (optional)

Your email address will not appear online and will be used only if the editor wishes to contact you personally for additional comments.