Don't get burned - Quick tips to ensure your data centre is safe

Don't get burned - Quick tips to ensure your data centre is safe

By:  Jonathan Batten  On: 14 Feb 2006 For: IT World Canada Creator

At TAB, we're continually called upon by data centre managers to help solve cooling issues in their facilities. Thermal management is a simple problem in a complex environment, and as every situation is different, there is no one "right way" carved in stone. Over the years, however, we've established a number of points to keep in mind so you can beat the heat.

At TAB, we're continually called upon by data centre managers to help solve cooling issues in their facilities. Thermal management is a simple problem in a complex environment, and as every situation is different, there is no one "right way" carved in stone. Over the years, however, we've established a number of points to keep in mind so you can beat the heat.

  1. Know Your Equipment: It is essential to understand the technology. Does it have front-to-back, side-to-side or top-to-bottom airflow requirements? For instance, devices with extensive back-panel connections may need side-to-side airflow for cooling, which means special rack space requirements.
  2. Hot Aisle/Cold Aisle Configuration: Keep your hot air hot and your cold air cold using the hot aisle/cold aisle floor layout. Simply put, enclosures face each other creating one aisle with cold air in front of the enclosures and one with hot air behind the enclosures. This way you separate the hot air from the cold air and effectively prevent air mixing, stopping hot air from flowing into the front of the servers in the next row.
  3. Aisle Spacing: For optimal airflow, as well as safe and easy service access, leave enough room between racks so that you can walk down both hot and cold aisles.
  4. Raise Your Cooling Capacity: It is recommended that you increase your cooling capacity by 10 to 15 percent per rack. Remember, you want the ability to lower the temperature of the equipment, not just maintain it.
  5. Cable Management: Appropriate management of data and network cables is key. Use racks with plenty of room for cable runs. Cables can obstruct airflow, so keep them neat and bundled to the side.
  6. No Solid Doors: Glass doors may add to the aesthetics of the data centre, but they, as well as any solid door option, can turn your rack into an oven. Air MUST be allowed to enter to cool the equipment.
  7. Blanking Panels: Don't forget to use blanking panels in open U spaces in the front of the rack. This will prevent hot air from recirculating from the back into the front of the equipment, providing a significant drop in the inlet temperature.
  8. Effective Raised Floor Design: Under-tile static pressure and local airflow can be affected simply by cutting oversized holes for cable runs. So cut with caution and use brushes or other airflow obstructers around wiring holes.
  9. Minimize Airflow Obstructions: Be aware that local airflow can be affected by air dams created by chilled water piping and cable trays underneath the raised floor. It may be wise to consider overhead cable management options which are typically less expensive and more flexible than under floor solutions
  10. Track Your Temperature: A simple thermometer may do, but given the increased heat densities it is better to deploy a series of sensors throughout the data centre or a thermal management system that monitors the internal enclosure environment.
  11. Perform Audits: Obtain regular audits to determine your cooling capacity and requirements. This is particularly important if you are moving to a higher density configuration.


Sign up for our Newsletters












Print |  Views: 707   |   Rating:offoffoffoffoff  (0 votes)
Rate this article on a scale of
1 to 5 stars,5 being the best.




Jonathan Batten Jonathan Batten is a contributor to the International Data Group (IDG) News Service, which publishes global technology stories from bureaus around the world to more than 300 publications in more than 60 countries.

Related Content

Twelve answers to your green IT questions
Twelve answers to your green IT questionsAre you ready to get with the environmental IT movement? Here are the answers to 12 fundamental questions around green IT.
Thin clients and open source the green IT winners
Thin clients and open source the green IT winnersGartner estimates that IT contributes two percent of global carbon dioxide emissions and predicts by 2010, environment-related issues will be among the top five IT management concerns
How 'hot' data centres can cook your goose – and IT equipment
How 'hot' data centres can cook your goose – and IT equipmentAn overheated data centre can cook one's IT equipment - literally, and land an IT manager in a hot spot. To try to avoid unpleasant surprises, IT managers are increasingly investing in computer-aided studies that map the airflow in data centers.
Gennum finds way to extend reach of displays
gennum corp. is expanding its activeconnect family of high-speed digital interfaces with a new connectivity solution to extend the reach of its displayport cable products. the burlington, ont., company's displayport interface for laptops, pcs, media servers, home theatres and dvrs, supports up to10.8 gb/

Comments (0)

No Comments!
Name: (required) eMail: (optional)

Your email address will not appear online and will be used only if the editor wishes to contact you personally for additional comments.